I am running NUT on Gentoo Linux to manage my Tripp Lite OMNI1000LCD UPS (USB) and to turn off the alarm one simply needs to run the following command, remember the username is what you defined in /etc/nut/upsd.users:
#upsrw -s ups.beeper.status=disabled -u nutusername
-p nutpassword theUPS@localhost:3493
immediately following that the command
upsc verified the change was live:
# upsc theUPS@localhost
battery.charge: 53
battery.type: PbAc
battery.voltage: 12.3
battery.voltage.nominal: 12.0
driver.name: newhidups
driver.parameter.port: auto
driver.version: 2.1.0
driver.version.data: TrippLite HID 0.1
(experimental)
driver.version.internal: 0.30
input.frequency: 59.8
input.voltage: 116.7
input.voltage.nominal: 120
output.frequency.nominal: 60
output.voltage.nominal: 120
ups.beeper.status: disabled
ups.delay.reboot: 65535
ups.delay.shutdown: 65535
ups.mfr: Tripp Lite
ups.model: TRIPP LITE UPS
ups.power.nominal: 1000
ups.serial: 692195 B
ups.status: OL CHRG
Now when there is a power loss to the unit it is silent and will shut down the computer when the low battery signal occurs.